Same kilowatt-hours, different cash case Steps 1. Define the physical reference: 1,000,000 kWh per year and an assumed 20% reduction give 200,000 kWh per year avoided. Record the technical evidence for that reduction separately from the price assumption. 2. Value the same avoided energy at each stated tariff. With flat prices of USD 0.12 and USD 0.18 per kWh, gross annual savings are USD 24,000 and USD 36,000 respectively. 3. Deduct the same USD 4,000 annual recurring cost in both cases. Net savings become USD 20,000 and USD 32,000. At USD 100,000 capital cost, simple payback changes from 5 years to 3.125 years. 4. Before a decision, investigate demand charges, time-of-use rates, baseline adjustments and contract terms. A lower bill after an intervention can also reflect a changed production level or weather; it is not automatically verified energy savings. Worked record Physical saving, both cases: ____________________ Case A · illustrative tariff: ____________________ Case B · illustrative tariff: ____________________ Difference: ____________________ Outside this screen: ____________________ Physical saving, both cases: 1,000,000 × 20% = 200,000 kWh/year Case A · illustrative tariff: USD 0.12/kWh → gross 24,000; net 20,000; simple payback 5 years Case B · illustrative tariff: USD 0.18/kWh → gross 36,000; net 32,000; simple payback 3.125 years Difference: 0 extra kWh saved; USD 12,000 more annual gross value under the higher price assumption Outside this screen: Demand charges, changing operations, tax, finance, degradation and replacement Save both cases rather than replacing the original tariff and forgetting why the result moved. For measurement and verification, define how the reference will be adjusted and how reporting-period energy will be measured. The calculator does not perform that verification or fetch an electricity contract. EVO: IPMVP measurement and verification — https://evo-world.org/en/products-services-mainmenu-en/protocols/ipmvp